Pump grinder for forced sewerage SANIBEST PRO , SFA (France)

SANIBEST Pro Forced Sewage Grinder Pump

The new ideal SANIBEST Pro macerator pump for public areas has a more powerful and quieter motor. Easy access to the controls, allows you to replace the capacitor, membrane, microswitch without dismantling the common cover. Designed for equipping toilets in hotel rooms, offices, restaurants, bars and other places of intensive use.

 

 

APPLICATION
This device is a compact pumping station designed to remove waste water from a toilet with a horizontal drain (outlet), shower, bidet or washbasin. 
This unit complies with EN 12050-3 and European regulations regarding electrical safety and electromagnetic compatibility.

SANIBEST Pro sewage pumps with grinder - a new generation of SFA forced sewage systems . Such a sewer unit is mounted next to the toilet and pumps fecal waste, including toilet paper and contaminated water.
The ability of the SANIBEST Pro fecal pump to work in public places is achieved by using a completely different grinding system in the unit, which is not located at the inlet to the sewer unit, as done in household appliances, but at the bottom of the installation case. The mechanism of the SANIBEST Pro sewage plant is made in the form of a chopping knife, which allows you to grind hygiene items that accidentally get into the pump. It should be added that the unit withstands a temperature of 70°C in short-term mode, which makes it possible to connect washing machines and dishwashers to SANIBEST Pro. The motor housing has a special heat exchanger that provides cooling for the oil in the motor.

INSTALLATION
The unit must be located in the same room as the toilet, and also other  sanitary equipment connected to it, if any. The unit must be freely accessible for inspection and maintenance purposes.
Installation and operation of the unit must comply with local regulations and EN 12056-4.
Position the pump so that it does not touch the wall of the room, the pump on a perfectly flat floor surface to prevent the proper operation of the anti-vibration clamps, properly fix the outlet pipe system so that the distance between the fixings does not exceed one meter.

OPERATING PRINCIPLE SEWER INSTALLATION SANIBEST Pro
After draining the water and raising the water level in the pump housing, the chopper automatically turns on and starts working within 4-7 seconds, depending on the length of the pressure line. The crushed effluent is then removed and the pump is ready for use again. 

 

 

For this model, it is possible to install a special sound alarm - SANIALARM
Accidental power outages or the accumulation of technical sediment leads to an increase in the level of wastewater in the pump and, as a result, in the connected plumbing. SANIALARM will warn you if the water in the pump rises above the operating level. SANIALARM is easily installed on the cover of the SFA pump and has a pressure sensor (membrane switch) and, if the water volume exceeds the maximum allowable level, the alarm emits a long sound (about 80 dB) until the problem is turned off and the problem is corrected.

ELECTRICAL CONNECTION
Electrical  connection should only be carried out after all necessary connections have been completed.
 Electrical installation must be carried out  by a qualified person. The appliance should be placed in such a way that access to an electrical outlet is provided. This appliance must be connected to earth (class I) and a high sensitivity differential circuit breaker (30mA).
The outlet must be used only for power supply apparatus. If the appliance's cable is damaged, it must be replaced by the manufacturer or its after-sales service to avoid risk.
Regulations and regulations
Comply with the regulations for electrical safety in bathrooms in force in the country of use.

COMMISSIONING
Once the electrical and hydraulic connections have been made, flush the water several times. The toilet must not leak. in case of a long absence, it is necessary to shut off the general water supply and protect the installation from frost by draining the water from the pump housing.

CLEANING AND REMOVING LIME
To remove limescale and cleaning the pumping station and the toilet bowl, you should regularly use a specially decalcifier designed for this purpose or a solution of 1 liter of 9% vinegar in 5 liters of water.

WARRANTY CONDITIONS< /strong>
The warranty period of the device is 2 years, starting from the date of purchase, provided that it is installed and used in accordance with the instructions.
CAUTION!!! The warranty applies only to the withdrawal of the toilet  paper, excrement and sewage. The warranty does not cover damage to the device caused by penetration of foreign bodies such as: cotton wool, tampons, sanitary napkins, panty liners, food, condoms, hair, metal, wood or plastic objects, or by pumping liquids such as oils. or solvents.

WARNING
This pumping station is designed to industry standards. It has undergone continuous quality control at the factory in accordance with the ISO 9001 standard. In order for your device to function properly, you must carefully follow the installation and maintenance instructions in the  instruction.
This device is not intended for individuals (including children) with  limited physical, sensory or mental capabilities, as well as lack of experience and knowledge in handling it, except when they use it under supervision and receive instructions on working with it from a person, responsible for their safety.
Supervise children and make sure they do not play with the appliance.

 

      Direct access to controls.

 

To order a spare part, just specify the pump name and part number

Pump grinder for forced sewerage SANIBEST PRO , SFA (France)

Reviews: 0

There are no reviews for this product.

Модули для Opencart