Pump grinder built-in fecal SANIPACK , SFA (France)

SANIPACK built-in fecal macerator

The new Sanipack (only 146 mm thick) is ideal for connecting a wall-hung toilet and can be completely built into the wall. One upper and two lower versatile nozzles allow you to simplify the connection of plumbing as much as possible. The powerful motor now pumps wastewater to a height of up to 5 m or a distance of up to 100 m.

 

 

APPLICATIONS
This device is a compact pumping station designed to remove waste water from a draining toilet (outlet), shower, bidet or washbasin. 
The machine complies with EN 12050-3 and the European regulations regarding electrical safety and electromagnetic compatibility.

INSTALLATION
The machine must be located in the same room as as well as the toilet, as well as other sanitary equipment connected to it, if any. The unit must be freely accessible for inspection and maintenance purposes.
Installation and operation of the unit must comply with local regulations and EN 12056-4.
Position the pump so that it does not touch the wall of the room, the pump on a perfectly flat floor surface to prevent the proper operation of the anti-vibration clamps, properly fix the outlet pipe system so that the distance between the fixings does not exceed one meter.

OPERATING PRINCIPLE SANIPACK SEWER PLANT
After draining the water and raising the water level in the housing, the pump motor automatically turns on and sets the knives in motion, which crush the particles present in the sewage within 4-6 seconds. The crushed effluent is removed and the pump is ready for use again.

 

 

For this model, it is possible to install a special sound alarm - SANIALARM
Accidental power outages or the accumulation of technical sediment leads to an increase in the level of wastewater in the pump and, as a result, in the connected plumbing. SANIALARM will warn you if the water in the pump rises above the working level. SANIALARM is easily installed on the cover of the SFA pump and has a pressure sensor (membrane switch) and, if the water volume exceeds the maximum allowable level, the alarm emits a long sound (about 80 dB) until the problem is turned off and the problem is corrected.

ELECTRICAL CONNECTION
Electrical  connection should only be carried out after all necessary connections have been made.
Electrical installation  must be  performed by a qualified person. The appliance should be placed in such a way that access to an electrical outlet is provided. This appliance must be connected to earth (class I) and a high sensitivity differential circuit breaker (30mA).
The outlet must be used only for power supply device. If the appliance's cable is damaged, it must be replaced by the manufacturer or its after-sales service to avoid risk.
Regulations and regulations
Comply with the regulations for electrical safety in bathrooms in force in the country of use.

COMMISSIONING
Once the electrical and hydraulic connections have been made, flush the water several times. The toilet must not leak. in case of a long absence, it is necessary to shut off the general water supply and protect the installation from frost by draining the water from the pump housing.

CLEANING AND REMOVING LIME
To remove limescale and cleaning the pumping station and the toilet bowl, you should regularly use a specially decalcifier designed for this purpose or a solution of 1 liter of 9% vinegar in 5 liters of water.

WARRANTY CONDITIONS< /strong>
The warranty period of the device is 2 years, starting from the date of purchase, provided that it is installed and used in accordance with the instructions.
CAUTION!!! The warranty applies only to the withdrawal of the toilet  paper, excrement and sewage. The warranty does not cover damage to the device caused by penetration of foreign bodies such as: cotton wool, tampons, sanitary napkins, panty liners, food, condoms, hair, metal, wood or plastic objects, or by pumping liquids such as oils. or solvents.

WARNING
This pumping station is designed to industry standards. It has undergone constant quality control at the factory in accordance with the ISO 9001 standard. In order for your machine to function properly, you must carefully follow the installation and maintenance instructions in the  instruction.
This machine is not intended for persons (including children) with  limited physical, sensory or mental capabilities, as well as lack of experience and knowledge in handling it, unless they use it under supervision and receive instructions on working with it from a person, responsible for their safety.
Supervise children and make sure they do not play with the appliance.

 

To provide access an inspection hatch must be provided for the chopper pump.

 